Purdue University Graduate School
Browse

COMPUTATIONAL AND EXPERIMENTAL INVESTIGATION OF MICROFLUIDICS INTO BIOPHYSICAL INTERACTION

Download (30.87 MB)
thesis
posted on 2024-04-24, 15:02 authored by Hui MaHui Ma

Microfluidic techniques have been widely adopted in biomedical research due to the pre- cise control of fluids, small volume requirement, low cost and etc, and have boosted the development of biomolecular interaction analysis, point-of-care diagnostics, and biosensors.

Protein-protein interaction plays a key role in biological, biomedical and pharmaceutical research. The technical development of biosensors, new drugs and vaccines, and disease diagnostics heavily rely on the characterization of protein-protein interaction kinetics. The current gold standard assays for measuring protein-protein interaction are surface plasmon resonance (SPR), and bio-layer interferometry (BLI). These commercial devices are accurate but expensive, however.

Here, I have developed new microfluidic techniques and models in protein-protein in- teraction kinetics measurement, rotational diffusion coefficient modeling, electrochemical impedance spectroscopy-based biosensors, and two-phase porous media flow models. Firstly, I applied particle diffusometry (PD) in the streptavidin-biotin binding kinetics measurement, utilizing a Y-junction microchannel. Secondly, to reduce solution volumes used in an analysis experiment, I designed a low-volume chip and coupled it with PD to measure the binding kinetics of human immunodeficiency virus p24 antibody-antigen interactions. Thirdly, con- sidering the Brownian motion of the non-symmetric particles, I developed a new model to efficiently compute particles’ rotational diffusion coefficients. Fourthly, to make economic biosensors to detect multiple biomarkers, I created a new chip, enabling hundreds of tests in a single droplet (∼ 50 μL) on one chip. Finally, to understand the liquid flow in porous media, such as nitrocellulose in lateral flow assays, I built a new two-phase porous media flow model based on the Navier-Stokes equation and compared it with experiments. These techniques and models underwent rigorous experimental and computational validation, demonstrating their effectiveness and performance.

History

Degree Type

  • Doctor of Philosophy

Department

  • Biomedical Engineering

Campus location

  • West Lafayette

Advisor/Supervisor/Committee Chair

Jacqueline C. Linnes

Advisor/Supervisor/Committee co-chair

Tamara L. Kinzer-Ursem

Additional Committee Member 3

Arezoo M. Ardekani

Additional Committee Member 4

Steven T. Wereley

Usage metrics

    Licence

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC